Connectors

Products

Back to product overview

IP68 Panel-mount insert Power socket

Download product sheet

Number Of Poles

  • 2
  • 3
Article Number THB.384.B2A THP.384.B2A
Number Of Contacts 2 2
Protection Degree IP68 IP68
Upper Temperature +125 °C +125 °C
Lower Temperature -40 °C -40 °C
Rated Voltage 400 400
Pollution Degree 2 2
Rated Current 17.5 A 17.5 A
Contact Terminal Contact screw terminals. For cable section < 1.0 mm² Piercing clip terminals max 1,5 mm²
Terminals Screw Piercing
Cable Section max 4,0 mm² 0,5 - 1,5 mm²
Min-max Cable Diameter 7,0-12,0 mm 7,0-12,0 mm
T Marking T85 °C T85 °C
Protection Degree Details 5 bar (50 m / 40 h) 5 bar (50 m / 40 h)
Impulse Withstand Category II II
Impulse Withstand Voltage 4 kV 4 kV
Tracking Index PTI 175 PTI 175
Lock Nuts PA66 GF UL94 V0 GWT 960°C black - grey RAL 7035 PA66 GF UL94 V0 GWT 960°C black - grey RAL 7035
Connector Housing PA66 UL94 V0/V2 GWT 850°C black - grey RAL 7035 PA66 UL94 V0/V2 GWT 850°C black - grey RAL 7035
Terminal Block Housing PA66 GF UL94 V0 GWT 960°C black - grey RAL 7035 PA66 GF UL94 V0 GWT 960°C black - grey RAL 7035
Grommets TPE TPE
Seals SEBS SEBS
Contact Screw Terminals Brass nickel plated OR Brass silver plated (THX.385.XXX.AG) Brass nickel plated OR Brass silver plated (THX.385.XXX.AG)
Standard / Piercing Screws M3 steel zinc plated M3 steel zinc brass plated
Standards EN60529:1991+A1:2000 EN60998-1:2004 EN60998-2-1:2004 EN61984:2001 EN60529:1991+A1:2000 EN60998-1:2004 EN60998-2-1:2004 EN61984:2001
Note Every connector housing type can be equipped with male or female contacts. For reasons pertaining to safety, only female contacts may be used in the live part of the connector. Every connector housing type can be equipped with male or female contacts. For reasons pertaining to safety, only female contacts may be used in the live part of the connector.
Characteristics differ between variants of a connector